Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | HENGFENGYOU |
Model Number : | KYN61 |
Certification : | ISO IEC CB COC KEMA SNI SABS CCC |
Price : | 200-20000/piece |
Payment Terms : | LC T/T |
Supply Ability : | 5000 piece/year |
Delivery Time : | 30 days |
KYN 61-40.5 Armoured Middle Metal Enclosed High Voltage Switchgear
1. Applications:
KYN61 series ht switchgear panel 35KV 40.5KV for electricity power distribution applied to power distribution system for 40.5kV with three-phase AC 50Hz single bus or single bus sectional system.Mainly used in power plants, substation, industrial and mining enterprises for power receiving and distribution, also for controlling, protecting and monitoring the circuit. It can be used for frequent operated occasions as well.
2. Environmental Conditions
· Suitable Altitude: 1000m ~ 4000m
· Suitable Temperature: -40℃ ~ +45℃
· Relative Humidity: Daily mean ≤95%, monthly mean ≤90%
· Gradation of Earthquake Damage: ≤ Level 8
3. Technical Data
No. | Item | Unit | Data |
1 | Rated voltage | KV | 40.5 |
2 | Rated current | A | 6,301,250,160,020,000,000 |
3 | Rated short-circuit current | KA | 20,25,31.5,40 |
4 | Rated peak withstand current | KA | 50,63,80,100 |
5 | Short-time withstand current(4s) | KA | 20,25,31.5,40 |
6 | Insulation: Power frequency/Lightning | KV | 95/185 |
7 | Protection class | IP4X | |
8 | Optional circuit breakers | ZN85, VD4, HD4, LN2-40.5 etc. | |
9 | Operating mechanism | Spring mechanism; Permanent magnetic actuator | |
10 | Operational power supply | V | DC:110,220; AC:110,220 |
11 | Overall dimension(Width*Depth*Height) | mm | 1400(1200)x2800x2600 1680x2800(3100)x2800 |
12 | Weight | KG | 1800 |
Main Functions:
Protective Function - It will indentify fault current automatically; realize
instantaneous current cutoff, time limited current break, regular
flow, directional flow, overvoltage, under-voltage, single phase
ground protection of small current ground system, and cooling load
start and inhibition of open circuit, and other functions.
Measurement Function - Measure three-phase current, three-phase voltage, active power,
reactive power, active energy, reactive energy, peak/valley
electricity, power factor and frequency, ect.
Controlling Function - It can realize on-site operation and remote control. Meanwhile,
achive fault location of circuit, fault isolation automatically,
resume power supply for the circuit without fault rapidly by
requirement; realize automatic load shedding under low frequency,
capacitor automatic cutting, automatic cutting of backup power, and
other controlling functions.
Communication Function - It can report fault, operation and controlling information to
appointed personnel through wireless public network or special
communication network; support various kinds of communication ways
and agreement; realize setting parameters modification by handhold
PDA. The controller releases the instruction of self-inspection
from PDA and feedback the self-inspection information to PDA
terminal.
Data Record Function - Record, save and run operation and fault information
automatically.
Synchronous Switching On/Off Function - According to the features of load, it searches zero crossing
point automatically; adapt itself to the discreteness of switch
parameter and impact of environment factors; realize synchronous
switching on/off; restrain over voltage of operation and inrush
phenomenon effectively, especially suitable for switching capacitor
and transformer.
Intelligence Function - It can carry out on-line conprehensive analysis of power network
parameters, on-line performance parameter measurement of circuit
breaker, and on-line programming; cooperate with the main station
pf power distribution automatic system; realize the function of
remote control management of switch device, and on-site, remote or
hierarchical control type power distribution automation system.
Load Management Function - Load management terminal cooperates with AVR series intelligent
compact solid insulation switch equipment. It is able to realize
load management function, solve the electricity fees issue
effectively for scattered residents customer, temporary customers,
and the customers who fail to pay the fee frequently.
![]() |